Views:

This article describes how to wire a ControlCenter CC-2 to FreeSpace IZA 190-HZ and FreeSpace IZA 250-LZ amplifiers.

 

Relevant Product(s)

  • FreeSpace IZA 190-HZ
  • FreeSpace IZA 250-LZ
  • ControlCenter CC-2

 

Procedure

ControlCenter CC-2 controllers have RJ-45 connectors (T568B). The ControlCenter CC-2 connects to REMOTE on the back of the amplifier with bare wire.

  1. Connect the RJ-45 end of the Ethernet cable to Main on the back of the controller.
  2. On the back of the amplifier,
    • Connect the White/Orange wire to PWR.
    • Connect the White/Green wire to VOL.
    • Connect the Green wire to A/B.
    • COM is unused.
       

     
  3. On the controller, set DIP switches 1, 3, and 5 to the ON position.  All other DIP switches should be down.
Add a comment